PART NUMBER DESCRIPTION
6SL3211-0AB12-5UA1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
AC 200-240V +10/-10% 47-63HZ
ANALOG INPUT
CT: 0.25KW; VT: 0.25KW CT-OVERLOAD: 150% 60S
150 X 90 X 116 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C
WITHOUT BOP
WITHOUT RS485-INTERFACE
6SL3211-0AB13-7UA1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
AC200-240V +10/-10% 47-63HZ
ANALOG INPUT
CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S
150 X 90 X 116 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG CWITHOUT BOP
WITHOUT RS485-INTERFACE
6SL3211-0AB15-5UA1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
1AC200-240V +10/-10% 47-63HZ
ANALOG INPUT
CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S
150 X 90 X 131 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C
WITHOUT BOP
WITHOUT RS485-INTERFACE
6SL3211-0AB17-5UA1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
1AC200-240V +10/-10% 47-63HZ
ANALOG INPUT
CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S
150 X 90 X 131 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C
WITHOUT BOP
WITHOUT RS485-INTERFACE
6SL3211-0AB21-1UA1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
1AC200-240V +10/-10% 47-63HZ
ANALOG INPUT
CT: 1.1KW; VT: 1.1KW CT-OVERLOAD: 150% 60S
160 X 140 X 142 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C
WITHOUT BOP
WITHOUT RS485-INTERFACE
6SL3211-0AB21-5UA1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
1AC200-240V +10/-10% 47-63HZ
ANALOG INPUT
CT: 1.5KW; VT: 1.5KW CT-OVERLOAD: 150% 60S
160 X 140 X 142 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C
WITHOUT BOP
WITHOUT RS485-INTERFACE
6SL3211-0AB22-2UA1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
1AC200-240V +10/-10% 47-63HZ
ANALOG INPUT
CT: 2.2KW; VT: 2.2KW CT-OVERLOAD: 150% 60S
181 X 184 X 152 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C
WITHOUT BOP
WITHOUT RS485-INTERFACE
6SL3211-0AB23-0UA1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
1AC200-240V +10/-10% 47-63HZ
ANALOG INPUT
CT: 3.0KW; VT: 3.0KW CT-OVERLOAD: 150% 60S
181 X 184 X 152 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C
WITHOUT BOP
WITHOUT RS485-INTERFACE
6SL3211-0AB12-5UB1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
1AC200-240V +10/-10% 47-63HZ
RS485-INTERFACE (USS-PROTOCOL)
CT: 0.25KW; VT: 0.25KW CT-OVERLOAD: 150% 60S
150 X 90 X 116 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C
WITHOUT BOP
WITHOUT ANA
6SL3211-0AB13-7UB1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
1AC200-240V +10/-10% 47-63HZ
RS485-INTERFACE (USS-PROTOCOL)
CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S
150 X 90 X 116 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C
WITHOUT BOP
WITHOUT ANA
6SL3211-0AB17-5UB1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
1AC200-240V +10/-10% 47-63HZ
RS485-INTERFACE (USS-PROTOCOL)
CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S
150 X 90 X 131 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C
WITHOUT BOP
WITHOUT ANA
6SL3211-0AB21-5UB1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
1AC200-240V +10/-10% 47-63HZ
RS485-INTERFACE (USS-PROTOCOL)
CT: 1.5KW; VT: 1.5KW CT-OVERLOAD: 150% 60S
160 X 140 X 142 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C
WITHOUT BOP
WITHOUT ANAL
6SL3211-0AB22-2UB1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
1AC200-240V +10/-10% 47-63HZ
RS485-INTERFACE (USS-PROTOCOL)
CT: 2.2KW; VT: 2.2KW CT-OVERLOAD: 150% 60S
181 X 184 X 152 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C
WITHOUT BOP
WITHOUT ANAL
6SL3211-0AB12-5BB1 SINAMICS G110 – CPM110 AC-DRIVE,BUILT IN CL. B FILTER
1AC200-240V +10/-10% 47-63HZ
RS485-INTERFACE (USS-PROTOCOL)
CT: 0.25KW; VT: 0.25KW CT-OVERLOAD: 150% 60S
150 X 90 X 116 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C
WITHOUT BOP
WITHOUT ANA
6SL3211-0AB13-7BB1 SINAMICS G110 – CPM110 AC-DRIVE,BUILT IN CL. B FILTER
1AC200-240V +10/-10% 47-63HZ
RS485-INTERFACE (USS-PROTOCOL)
CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S
150 X 90 X 116 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C
WITHOUT BOP
WITHO
6SL3211-0AB13-7BB1 SINAMICS G110 – CPM110 AC-DRIVE,BUILT IN CL. B FILTER
1AC200-240V +10/-10% 47-63HZ
RS485-INTERFACE (USS-PROTOCOL)
CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S
150 X 90 X 131 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C
6SL3211-0AB21-5AB1 SINAMICS G110 – CPM110 AC-DRIVE,BUILT IN CL. A FILTER
1AC200-240V +10/-10% 47-63HZ
RS485-INTERFACE (USS-PROTOCOL)
CT: 1.5KW; VT: 1.5KW CT-OVERLOAD: 150% 60S
160 X 140 X 142 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C
WITHOUT BOP
WITHOUT ANA
6SL3211-0AB22-2AB1 SINAMICS G110 – CPM110 AC-DRIVE,BUILT IN CL. A FILTER
1AC200-240V +10/-10% 47-63HZ
RS485-INTERFACE (USS-PROTOCOL)
CT: 2.2KW; VT: 2.2KW CT-OVERLOAD: 150% 60S
181 X 184 X 152 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C
WITHOUT BOP
WITHOUT ANA
6SL3211-0AB23-0UA1 SINAMICS G110 – CPM110 AC-DRIVE, WITHOUT FILTER
1AC200-240V +10/-10% 47-63HZ
ANALOG INPUT
CT: 3.0KW; VT: 3.0KW CT-OVERLOAD: 150% 60S
181 X 184 X 152 (H x W x D)
PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C
WITHOUT BOP
WITHOUT RS485-INTERFACE
6SL3255-0AA00-4BA1 SINAMICS G110/G120
BASIC OPERATOR PANEL (BOP)

 

Add a Review